141 research outputs found

    Gesture-Controlled Interface for Contactless Control of Various Computer Programs with a Hooking-Based Keyboard and Mouse-Mapping Technique in the Operating Room

    Get PDF
    We developed a contactless interface that exploits hand gestures to effectively control medical images in the operating room. We developed an in-house program called GestureHook that exploits message hooking techniques to convert gestures into specific functions. For quantitative evaluation of this program, we used gestures to control images of a dynamic biliary CT study and compared the results with those of a mouse (8.54±1.77 s to 5.29±1.00 s; p<0.001) and measured the recognition rates of specific gestures and the success rates of tasks based on clinical scenarios. For clinical applications, this program was set up in the operating room to browse images for plastic surgery. A surgeon browsed images from three different programs: CT images from a PACS program, volume-rendered images from a 3D PACS program, and surgical planning photographs from a basic image viewing program. All programs could be seamlessly controlled by gestures and motions. This approach can control all operating room programs without source code modification and provide surgeons with a new way to safely browse through images and easily switch applications during surgical procedures

    Relationship between Altitude and Lithium in Groundwater in the United States of America: Results of a 1992–2003 Study

    Get PDF
    Therapeutic dosages of lithium are known to reduce suicide rates, which has led to investigations of confounding environmental risk factors for suicide such as lithium in groundwater. It has been speculated that this might play a role in the potential relationship between suicide and altitude. A recent study in Austria involving geospatial analysis of lithium in groundwater and suicide found lower levels of lithium at higher altitudes. Since there is no reason to suspect this correlation is universal given variation in geology, the current study set out to investigate the relationship between altitude and lithium in groundwater in the United States of America (USA). The study utilised data extracted from the National Water-Quality Assessment programme implemented by the United States Geological Survey that has collected 5,183 samples from 48 study areas in USA for the period of 1992 to 2003. Lithium was the trace-element of interest and 518 samples were used in the current analyses. Due to uneven lithium sampling within the country, only the states (n=15) with the highest number of lithium samples were included. Federal information processing standard codes were used to match data by county with the mean county altitude calculated using altitude data from the Shuttle Radar Topography Mission. The study was controlled for potential confounding factors known to affect levels of lithium in groundwater including aquifer, aquifer type, lithology, water level and the depths of wells. The levels of lithium in groundwater, increased with altitude (R2 = 0.226, P \u3c0.001) during the study period. These findings differ from the Austrian study and suggest a need for further research accounting also for the impact of geographical variation

    Validation of a CT-guided intervention robot for biopsy and radiofrequency ablation: experimental study with an abdominal phantom

    Get PDF
    PURPOSE:We aimed to evaluate the accuracy of a needle-placement robot for biopsy and radiofrequency ablation on an abdominal phantom.METHODS:A master-slave robotic system has been developed that includes a needle-path planning system and a needle-inserting robot arm with computed tomography (CT) and CT fluoroscopy guidance. For evaluation of its accuracy in needle placement, a commercially available abdominal phantom (Model 057A; CIRS Inc.) was used. The liver part of the phantom contains multiple spherical simulated tumors of three different size spheres. Various needle insertion trials were performed in the transverse plane and caudocranial plane two nodule sizes (10 mm and 20 mm in diameter) to test the reliability of this robot. To assess accuracy, a CT scan was performed after each trial with the needle in situ.RESULTS:The overall error was 2 mm (0–2.6 mm), which was calculated as the distance from the planned trajectory before insertion to the actual needle trajectory after insertion. The standard deviations of the insertions on two nodules (10 mm and 20 mm in diameter) were 0.5 mm and 0.2 mm, respectively.CONCLUSION:The CT-compatible needle placement robot for biopsy and radiofrequency ablation shows relatively acceptable accuracy and could be used for radiofrequency ablation of nodules ≥10 mm under CT fluoroscopy guidance

    Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway

    Get PDF
    parameters on the correct measurement of the airway dimension. Materials and Methods: An airway phantom with 11 poly-acryl tubes of various lumen diameters and wall thicknesses was scanned using a 16-MDCT (multidetector CT) at various tilt angles (0, 30, 45, and 60 ). The CT images were reconstructed at various reconstruction kernels and thicknesses. The axis of each airway was determined using the 3D thinning algorithm, with images perpendicular to the axis being reconstructed. The luminal radius and wall thickness was measured by the full-width-half-maximum method. The influence of the CT parameters (the size of the airways, obliquity on the radius and wall thickness) was assessed by comparing the actual dimension of each tube with the estimated values. Results: The 3D thinning algorithm correctly determined the axis of the oblique airway in all tubes (mean error: 0.91+-0.82 ). A sharper reconstruction kernel, thicker image thickness and larger tilt angle of the airway axis resulted in a significant decrease of the measured wall thickness and an increase of the measured luminal radius. Use of a standard kernel and a 0.75-mm slice thickness resulted in the most accurate measurement of airway dimension, which was independent of obliquity. Conclusion: The airway obliquity and imaging parameters have a strong influence on the accuracy of the airway wall measurement. For the accurate measurement of airway thickness, the CT images should be reconstructed with a standard kernel and a 0.75 mm slice thickness.This work was supported by the Korea Science and Engineering Foundation (KOSEF) grant funded by the Korea government (MOST) (No. R01-2006-000-11244-0)

    Review: Magnetic Resonance Spectroscopy Studies of Pediatric Major Depressive Disorder

    Get PDF
    Introduction. This paper focuses on the application of Magnetic Resonance Spectroscopy (MRS) to the study of Major Depressive Disorder (MDD) in children and adolescents. Method. A literature search using the National Institutes of Health's PubMed database was conducted to identify indexed peer-reviewed MRS studies in pediatric patients with MDD. Results. The literature search yielded 18 articles reporting original MRS data in pediatric MDD. Neurochemical alterations in Choline, Glutamate, and N-Acetyl Aspartate are associated with pediatric MDD, suggesting pathophysiologic continuity with adult MDD. Conclusions. The MRS literature in pediatric MDD is modest but growing. In studies that are methodologically comparable, the results have been consistent. Because it offers a noninvasive and repeatable measurement of relevant in vivo brain chemistry, MRS has the potential to provide insights into the pathophysiology of MDD as well as the mediators and moderators of treatment response

    Perfusion parameters as potential imaging biomarkers for the early prediction of radiotherapy response in a rat tumor model

    Get PDF
    PURPOSEWe aimed to compare various tumor-related radiologic morphometric changes and computed tomography (CT) perfusion parameters before and after treatment, and to determine the optimal imaging assessment technique for the prediction of early response in a rat tumor model treated with radiotherapy.METHODSAmong paired tumors of FN13762 murine breast cancer cells implanted bilaterally in the necks of eight Fischer rats, tumors on the right side were treated with a single 20 Gy dose of radiotherapy. Perfusion CT studies were performed on day 0 before radiotherapy, and on days 1 and 5 after radiotherapy. Variables based on the size, including the longest diameter, tumor area, and volume, were measured. Quantitative perfusion analysis was performed for the whole tumor volume and permeabilities and blood volumes (BVs) were obtained. The area under the curve (AUC) difference in the histograms of perfusion parameters and texture analyses of uniformity and entropy were quantified. Apoptotic cell density was measured on pathology specimens immediately after perfusion imaging on day 5.RESULTSOn day 1 after radiotherapy, differences in size between the irradiated and nonirradiated tumors were not significant. In terms of percent changes in the uniformity of permeabilities between tumors before irradiation and on day 1 after radiotherapy, the changes were significantly higher in the irradiated tumors than in the nonirradiated tumors (0.085 [−0.417, 0.331] vs. −0.131 [−0.536, 0.261], respectively; P = 0.042). The differences in AUCs of the histogram of voxel-by-voxel vascular permeability and BV in tumors between day 0 and day 1 were significantly higher in treated tumors compared with the control group (permeability, 21.4 [−2.2, 37.5] vs. 9.5 [−8.9, 33.8], respectively, P = 0.030; BV, 52.9 [−6186.0, 419.2] vs. 11.9 [−198.3, 346.7], respectively, P = 0.049). Apoptotic cell density showed a significantly positive correlation with the AUC difference of BV, the percent change of uniformity in permeability and BV (r=0.202, r=0.644, and r=0.706, respectively).CONCLUSIONBy enabling earlier tumor response prediction than morphometric evaluation, the histogram analysis of CT perfusion parameters appears to have a potential in providing prognostic predictive information in an irradiated rat model
    corecore